Home Enterprise Dell PowerEdge T560 Tower Server Review

Dell PowerEdge T560 Tower Server Review

by Charles P. Jefferies
Dell PowerEdge T560 Tower - Interior

The Dell PowerEdge T560 Tower Server is purpose-built for on-premise IT, virtualization, database management, AI inferencing, private cloud, and more. It’s powered by fourth-generation Intel Xeon Scalable CPUs and supports 24 storage drives.

The Dell PowerEdge T560 Tower Server is purpose-built for on-premise IT, virtualization, database management, AI inferencing, private cloud, and more. It’s powered by fourth-generation Intel Xeon Scalable CPUs and supports 24 storage drives.

Dell PowerEdge T560 Tower

Dell PowerEdge T560 Tower Server Specifications

Rack servers aren’t practical for every business, especially if you don’t have a data center. This is doubly true at the edge where the notion of a traditional server room is non-existent. That’s where the PowerEdge T560 Tower Server comes in, with an office-friendly (low noise) design. The larger chassis also allows some unique configurations that aren’t possible on rack-mount servers, such as mixing 2.5″ bays with 3.5″ bays on the front backplane.

The T560 supports two 32-core fourth-generation Intel Xeon Scalable processors (“Sapphire Rapids”), 1TB of memory (16 RDIMM slots), and many possible combinations of drives. It’s no small tower in that sense, equating to 4.5U in a rack, and supporting eight cooling fans.

This tower also has tons of expansion with six PCIe slots, two of which are x16 Gen5. It fits two double-wide 300-watt GPUs or six single-slot 75-watt GPUs.

The PowerEdge T560’s full specifications are as follows:

Processor Up to two 4th generation Intel Xeon Scalable processors, up to 32 cores per socket
Memory
  • 16 DDR5 DIMM slots, 1TB max
  • Registered ECC DDR5 DIMMs only
Storage Controllers
  • Internal PERC: fPERC H965i, fPERC H755N, fPERC H755, fPERC H355, fPERC HBA355i
  • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSD drives, or USB
  • External HBA (non-RAID): PERC HBA355e
  • Software RAID: S160 (for NVMe drives only)
Drive Bays Front Bays:

  • Internal PERC: fPERC H965i, fPERC H755N, fPERC H755, fPERC H355, fPERC HBA355i
  • Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSD drives, or USB
  • External HBA (non-RAID): PERC HBA355e
  • Software RAID: S160 (for NVMe drives only)
Power Supplies
  • 2400 W Platinum 100—240 VAC or 2400 W 240 VDC, hot swap redundant
  • 1800 W Titanium 200—240 VAC or 1800 W 240 VDC, hot swap redundant
  • 1400 W Platinum 100—240 VAC or 1400 W 240 VDC, hot swap redundant
  • 1100 W Titanium 100—240 VAC or 1100 W 240 VDC, hot swap redundant
  • 1100 LVDC -48 — (-60) VDC, hot swap redundant
  • 800 W Platinum 100—240 VAC or 800 W 240 VDC, hot swap redundant
  • 700 W Titanium 200—240 VAC or 700 W 240 VDC, hot swap redundant
  • 600 W Platinum 100—240 VAC or 600 W 240 VDC, hot swap redundant
Fans Up to eight Standard (STD) fans or High performance (HPR) fans
Dimensions Height — 464.0 mm (18.26 inches) (with feet)

  •  508.8 mm (20.03 inches) (with caster wheels)
  •  446.0 mm (17.60 inches) (without feet)

Width — 200.0 mm (7.87 inches)

  • Depth — 678.2 mm (26.70 inches) (with bezel)
  •  660.6 mm (26 inches) (without bezel)
Form Factor 4.5U tower server
Embedded Management
  • iDRAC9
  • iDRAC Direct
  • iDRAC RESTful API with Redfish
  • iDRAC Service Module
  • Quick Sync 2 wireless module
OpenManage Software
  • OpenManage Enterprise
  • OpenManage Power Manager plugin
  • OpenManage Service plugin
  • OpenManage Update Manager plugin
  • CloudIQ for PowerEdge plug in
  • OpenManage Enterprise Integration for VMware vCenter
  • OpenManage Integration for Microsoft System Center
  • OpenManage Integration with Windows Admin Center
Mobility OpenManage Mobile
OpenManage Integrations
  • BMC Truesight
  • Microsoft System Center
  • OpenManage Integration with ServiceNow
  • Red Hat Ansible Modules
  • Terraform Providers
  • VMware vCenter and vRealize Operations Manage
Security
  • Cryptographically signed firmware
  • Data at Rest Encryption (SEDs with local or external key mgmt)
  • Secure Boot
  • Secure Erase
  • Secured Component Verification (Hardware integrity check)
  • Silicon Root of Trust
  • System Lockdown (requires iDRAC9 Enterprise or Datacenter)
  • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ
Embedded NIC 2 x 1GbE LOM on Planar
Network Options 1 x OCP x8 card 3.0

Note: The system allows both LOM on planar and OCP card to be installed on the system

GPU Options Up to 2 x 300 W DW or 6 x 75 W SW
Ports Front:

  • 1 x USB 2.0
  • 1 x USB 3.0
  • 1 x iDRAC Direct (Micro-AB USB) port

Rear:

  • 1 x USB 2.0
  • 1 x USB 3.0
  • 1 x Serial port (optional)
  • 1 x Dedicated iDRAC (RJ45) port
  • 1 x VGA port
  • 2 x Ethernet ports

Internal:

  • USB 3.0 (optional)
PCIe Up to six PCIe slots:

  • Slot 1: x16 Gen5 Full height, Full length
  • Slot 2: x16 Gen5 Full height, Full length
  • Slot 3: x16 Gen4 Full height, Half length
  • Slot 4: x16 Gen4 Full height, Half length
  • Slot 5: x16 (x8 lanes) Gen4 Full height, Half length
  • Slot 6: x16 Gen4 Full height, Half length
Operating System and Hypervisors
  • Canonical Ubuntu Server LTS
  • Microsoft Windows Server with Hyper-V
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
  • VMware ESXi
  • For specifications and interoperability details, see Dell.com/OSsupport

Dell PowerEdge T560 Tower Server Build and Design

Tower servers are rarely small and the PowerEdge T560 certainly isn’t, at 18.3 by 7.9 by 26.7 inches (HWD). This 4.5U tower is impressive from every angle, starting on the front with its hot-swap drive bays. Ours has eight 2.5- and eight 3.5-inch bays, with two M.2 RAID-able redundant BOSS drives on the right.

Front ports include one USB 2.0, one USB 3.0, and an iDRAC Direct (Micro-AB USB) port.

Dell PowerEdge T560 Tower - Front

To the right of the 3.5-inch drive bays are the NVMe M.2 boot drives.

Dell PowerEdge T560 Tower - M.2 Boot Drives

On the rear, the tower has one USB 2.0, one USB 3.0, an optional serial port, 1GbE for iDRAC, one VGA, and two Ethernet ports and OCP slot. Another USB 3.0 port is optional.

Dell PowerEdge T560 Tower - Rear

The tower’s side door is removed for interior access; the layout looks much like a standard server turned on its side. Most of the interior is covered with a massive airflow guide.

Dell PowerEdge T560 Tower - Interior

Eight hot-swap fans go down the centerline; squeezing the orange tabs allows them to come free.

Dell PowerEdge T560 Tower - Fans

Each Xeon CPU has a huge tower-style heatsink and is flanked by eight DIMM slots. The T560 supports up to 1TB of total RAM.

Dell PowerEdge T560 Tower - CPUs

Here are views behind the drive bays, including the NVMe RAID card, there’s a second card in this build for the HDDs.

Dell PowerEdge T560 Tower - Drive Bays

Dell PowerEdge T560 Tower - RAID Card

We have an exceptional configuration with five NVIDIA L4 GPUs, making it an ideal inferencing platform.

Dell PowerEdge T560 Tower - Nvidia L4s

Sandwiched between the GPUs is another small airflow shield for the OCP NIC.

Dell PowerEdge T560 Tower - OCP NIC

The dual hot-swap power supplies are at the top.

Dell PowerEdge T560 Tower - Power Supplies

See our walkaround video on Instagram.

Dell PowerEdge T560 Tower Server Performance

Our review unit has the following configuration:

  • 2x Intel Xeon Gold 6448Y (32-core/64-thread each, 225-watt TDP, 2.1-4.1GHz)
  • 8x 1.6TB Solidigm P5520 SSDs w/ PERC 12 RAID card
  • 5x NVIDIA L4 GPUs
  • 8x 64GB RDIMMs

For storage testing, we leveraged the SSDs connected to the PERC 12 RAID card in a JBOD and RAID 6 configurations. This is different than using native NVMe, where each SSD would have its own x4 connection to the motherboard.

VDBench Workload Analysis

When it comes to benchmarking storage devices, application testing is best, and synthetic testing comes in second place. While not a perfect representation of actual workloads, synthetic tests help baseline storage devices with a repeatability factor that makes it easy to make apples-to-apples comparisons between competing solutions. These workloads offer a range of testing profiles ranging from “four corners” tests and common database transfer size tests to trace captures from different VDI environments.

All of these tests leverage the common vdBench workload generator, with a scripting engine to automate and capture results over a large compute testing cluster. This allows us to repeat the same workloads across a wide range of storage devices, including flash arrays and individual storage devices. Our testing process for these benchmarks fills the entire drive surface with data and then partitions a drive section equal to 25% of the drive capacity to simulate how the drive might respond to application workloads. This differs from full entropy tests, which use 100 percent of the drive and take them into a steady state. As a result, these figures will reflect higher-sustained write speeds.

Profiles:

  • 4K Random Read: 100% Read, 128 threads, 0-120% iorate
  • 4K Random Write: 100% Write, 128 threads, 0-120% iorate
  • 64K Sequential Read: 100% Read, 32 threads, 0-120% iorate
  • 64K Sequential Write: 100% Write, 16 threads, 0-120% iorate
  • 64K Random Read: 100% Read, 32 threads, 0-120% iorate
  • 64K Random Write: 100% Write, 16 threads, 0-120% iorate
  • Synthetic Database: SQL and Oracle
  • VDI Full Clone and Linked Clone Traces

Starting with 4K random read, we saw the T560 reach 1.79 million IOPS in RAID6 and 4.86 million IOPS in JBOD. The latency was well controlled except for the end of the JBOD results, where we saw a minor spike.

Dell PowerEdge T560 4K Random Read

Random write 4K saw a sharp spike for the RAID6 array; it didn’t go past 415,000 IOPS. The JBOD configuration, on the other hand, reached 3.9 million IOPS before showing minor instability. Again, though, we see relatively stable latency until the spikes.

Dell PowerEdge T560 Random Write 4K

Next up is sequential read 64k; the T560’s RAID6 array achieved 8.2GB/s while the JBOD configuration reached nearly 23GB/s. The lines show no instability.

Dell PowerEdge T560 Sequential Read 64kWe saw another sharp spike for the T560’s RAID6 array in the sequential write 64k test, where it hit a wall at about 4GB/s. The JBOD configuration went up to about 16.5GB/s, with some instability past 14GB/s.

Dell PowerEdge T560 Sequential Write 64k

Our mixed 70/30 8K test showed relatively smooth lines; the RAID6 array reached about 670,000 IOPS and the JBOD array 1.93 million IOPS. Latencies in both cases remained controlled.

Dell PowerEdge T560 Mixed 70/30 8K

The next tests are our SQL workloads. We continue to see stable latency, and here there are no spikes. The RAID6 array peaked just past 4 million IOPS while the JBOD configuration topped 14 million IOPS.

Dell PowerEdge T560 SQL Workload

We also run an Oracle SQL workload test where the results were similar, the RAID6 array this time going further past 4 million IOPS and the JBOD configuration creeping slightly over 14 million IOPS.

Dell PowerEdge T560 Oracle Workload

Windows Server 2022 Performance Benchmarks

For our comparison, we selected the previously tested R760. Here is the comparison between the CPU’s. Both have the same number of cores, although the Xeon 6448Y CPUs inside the T560 have an edge on overall clockspeed compared to the Xeon 6430s inside the R760.

Dell PowerEdge T560 – Intel Xeon 6448Y Dell PowerEdge R760 – Intel Xeon 6430
Total Cores 32 32
Total Threads 64 64
Max Turbo Frequency 4.10 GHz 3.40 GHz
Processor Base Frequency 2.10 GHz 2.10 GHz

Cinebench R23 and R24

Maxon’s Cinebench R23 is a CPU rendering benchmark that utilizes all CPU cores and threads. We ran it for both multi- and single-core tests. Higher scores are better.

With the recent release of the 24 version, it introduced a new scoring system and the ability to run on multiple GPU’s.

Test Dell PowerEdge T560 (2x Xeon Gold 6448Y)
Cinebench R23 Multi 73,622
Cinebench R23 Single 1186
Cinebench R24 GPU 97,984
Cinebench R24 CPU Multi 3,976
Cinebench R24 CPU Single 3,976

Blender CLI

Blender benchmark measures the 3D rendering performance of a CPU or GPU by rendering a 3D scene in the Blender software. It provides a score that can be used to compare the performance of different systems and components. The numbers are in samples per minute.

Test Dell PowerEdge T560 (2x Xeon Gold 6448Y, 5x NVIDIA L4) Dell PowerEdge R760 (2x Xeon Gold 6430, 1x NVIDIA A2)
CPU Blender CLI – Monster 582.085675 576.928413
CPU Blender CLI – Junkshop 383.546707 376.557690
CPU Blender CLI – Classroom 275.857847 281.536442
GPU Blender CLI – Monster 2,547.287378 479.238127
GPU Blender CLI – Junkshop 1,348.087892 302.355378
GPU Blender CLI – Classroom 1,229.122455 248.540754

Geekbench 6

Geekbench is a cross-platform benchmark. We use the CPU benchmark, which has multiple workloads to model real-world tasks and applications.

Test Dell PowerEdge T560 (2x Xeon Gold 6448Y) Dell PowerEdge R760 (2x Xeon Gold 6430)
Geekbench 6 CPU Multi Score 18,572 12,971
Geekbench 6 CPU Single Score 1,734 12,971
Geekbench 6 GPU dGPU Score – OpenCL 157,380 Untested

y-cruncher

y-cruncher is a multi-threaded and scalable program that can compute Pi and other mathematical constants to trillions of digits. Since its launch in 2009, it has become a popular benchmarking and stress-testing application for overclockers and hardware enthusiasts. Here again we see that the PowerEdge R760’s Xeon Gold chips have a slight performance advantage.

Test Dell PowerEdge T560 (2x Xeon Gold 6448Y) Dell PowerEdge R760 (2x Xeon Gold 6430)
y-cruncher 1b Compute Time 7.332 7.306
y-cruncher 2.5b Compute Time 20.102
y-cruncher 10b Compute Time 97.32 91.435

GPUPI

GPUPI 3.3.3 is a version of the lightweight benchmarking utility designed to calculate π (pi) to billions of decimals using hardware acceleration through GPUs and CPUs. It leverages the computing power of OpenCL and CUDA which includes both central and graphic processing units. We ran CUDA on the 5x L4’s.

Application Dell PowerEdge T560 (2x Xeon Gold 6448Y) with 5X NVIDIA L4
GPUPI v3.3 – 1B 0sec 850ms
GPUPI v3.3 – 32B 50sec 361ms

UL Procyon AI Inference (CPU)

UL’s Procyon AI Inference benchmark suite tests how various AI inference engines perform using state-of-the-art neural networks. We run these tests on the CPU only. The numbers below are average inference times; the overall score is the last row.

Test Dell PowerEdge T560 (2x Xeon Gold 6448Y) Dell PowerEdge R760 (2x Xeon Gold 6430)
MobileNet V3 2.60 3.05
ResNet 50 6.12 6.79
Inception V4 19.59 20.55
DeepLab V3 23.68 31.27
YOLO V3 29.63 32.58
REAL-ESRGAN 1468.64 1498.36
Overall Score 191 169

GROMACS CUDA on the Dell T560 Tower Server

To unlock the full potential of the Dell T560 tower server equipped with 5 NVIDIA L4 GPUs, we source compiled GROMACS, a molecular dynamics software, specifically for CUDA. This bespoke compilation was to leverage the parallel processing capabilities of the 5 NVIDIA L4 GPUs, essential for accelerating computational simulations.

The process involved the utilization of nvcc, NVIDIA’s CUDA compiler, along with many iterations of the appropriate optimization flags to ensure that the binaries were properly tuned to the server’s architecture. The inclusion of CUDA support in the GROMACS compilation allows the software to directly interface with the GPU hardware, which can drastically improve computation times for complex simulations.

The Test: Custom Protein Interaction in Gromacs

Leveraging a community-provided input file from our diverse Discord, which contained parameters and structures tailored for a specific protein interaction study, we initiated a molecular dynamics simulation. The results were remarkable— the system achieved a simulation rate of 170.268 nanoseconds per day.

GPU System ns/day core time (s)
NVIDIA A4000 Whitebox AMD Ryzen 5950x 84.415 163,763
RTX NVIDIA 4070 Whitebox AMD Ryzen 7950x3d 131.85 209,692.3
5x NVIDIA L4 Dell T560 w/ 2x Intel Xeon Gold 6448Y 170.268 608,912.7

Significance of the Simulation Speed

The speed at which molecular simulations can be run is critical in various industries. For instance, in pharmaceuticals, rapid simulation capabilities can significantly accelerate drug discovery by enabling researchers to quickly iterate through molecular designs and interactions.

In material sciences, it can expedite the development of new materials with desired properties. The rate of 170.268 ns/day implies that simulations that would take nearly two weeks on much older servers can now be completed in just a single day on the Dell T560 equipped with the modest NVIDIA L4. This not only enhances productivity but also opens new frontiers in real-time data analysis and decision-making.

The GROMACS simulation output form the T560

Impact on Scientific Research

An interaction with a laboratory that is currently running similar simulations on 10-year-old hardware provided a stark contrast. Their existing setup takes 24 hours to complete what the Dell T560 can achieve in mere minutes. This comparison not only highlights the advancements in modern processors but also showcases the value that current hardware can bring to scientific research.

DALL·E 2023-11-03 15.08.18 - Photo depicting a high-powered computational simulation of molecular dynamics with a focus on GROMACS. The image shows a complex 3D molecular structure

With the Dell T560 tower server, researchers could conduct more experiments in a shorter timeframe, improving the iterative cycle of hypothesis and testing that is central to scientific advancement. It means computational experiments that were once considered too resource-intensive for routine exploration are now feasible.

AI Applications of Compute Performance

The compute performance demonstrated by the Dell T560 has wide-reaching implications in the field of research. It’s not just about speed but also about the complexity and size of the problems that can now be tackled. Large-scale simulations that model entire biological systems, complex chemical reactions, or even ecological models become more viable with this kind of computational power.

With the advent of AI and machine learning, the high throughput of molecular dynamics simulations enables the generation of massive datasets necessary for training sophisticated models. These models can lead to breakthroughs in predictive biology, novel materials, and next-generation computational chemistry.

Conclusion

The Dell PowerEdge T560 Tower brings remarkable flexibility for general server usage and advanced or specialized tasks, including GPU, compute, and data science. It matches, and in some ways exceeds, rack servers in expansion and power, with two Intel “Sapphire Rapids” Xeon scalable processors, 1TB of RAM, many storage drive configurations, and multiple GPU support, yet its tower form factor doesn’t require a data center. Though clearly not silent depending on workload, its fans are quiet enough that it can be used in an office environment.

Dell PowerEdge T560 Tower - Nvidia L4s

Our testing touched all areas of the PowerEdge T560’s capabilities; it showed solid numbers in our storage and CPU testing and flexed its muscle in GPU testing with our exceptional configuration of five NVIDIA L4 GPUs. We also appreciated the tower’s simple serviceability. For commendable expansion and adaptability to even the most demanding AI workloads, the PowerEdge T560 Tower gets our strong recommendation and recognition as a “Best of 2023” winner.

T560 Configurator